PV string · inverter · battery

Solar Design Calculator

Check panel strings, inverter limits, cable voltage drop and battery capacity from one design workspace.

Check Battery compatibility
Total panels 16 7.28 kW nominal PV
Usable battery 18.42 kWh 3.20 h at 5.75 kW
Estimated daily PV 28.8 kWh +18.8 kWh after daily load
Overall assessment Check 0 checks need attention

01

Design conditions

These assumptions drive every string and battery calculation.

02

Inverter

Select the inverter whose limits will be used for the assessment.

Rated output
12.00 kW
Maximum PV power
15.60 kW
Maximum PV voltage
800 V
MPPT range
200–650 V
Startup voltage
160 V
MPPT trackers
2
String inputs
2 + 1
Operating current
26 A + 13 A
Maximum Isc
34 A + 17 A

03

PV strings

Add up to ten string groups and assign every group to a physical inverter MPPT.

String MPPT Panel model Series Parallel Cable Length Actions
m
m

PV calculation results

Status String MPPT Panels Cold Voc Hot Vmp Cold Vmp Max Isc Operating current Nominal Voltage drop
Pass String 1 MPPT 1 8 414.6 V 276.9 V 307.2 V 12.01 A 11.35 A 3.64 kW 4.32 V · 1.56%
Pass String 2 MPPT 2 8 414.6 V 276.9 V 307.2 V 12.01 A 11.35 A 3.64 kW 4.32 V · 1.56%
String 1 checks Pass
  • Cable voltage drop: 1,56 % is within the 5 % limit.
  • Inverter maximum voltage: 518,29 V is within the 800 V limit.
  • MPPT 1 operating current: 11,35 A is within the 26 A limit.
  • MPPT 1 minimum: 276,88 V meets the 200 V minimum.
  • MPPT 1 maximum: 307,21 V is within the 650 V limit.
String 2 checks Pass
  • Cable voltage drop: 1,56 % is within the 5 % limit.
  • Inverter maximum voltage: 518,29 V is within the 800 V limit.
  • MPPT 2 operating current: 11,35 A is within the 13 A limit.
  • MPPT 2 minimum: 276,88 V meets the 200 V minimum.
  • MPPT 2 maximum: 307,21 V is within the 650 V limit.

04

Battery bank

Select a reviewed SQL battery configuration approved or conditionally screened for this inverter.

Compare all batteries

Selected battery configuration

Voltage class
LV
Voltage range
44.8–57.6 V
Usable per system
9.21 kWh
Power per system
10.24 kW
Recommended quantity
2
Maximum quantity
32
BMS
CAN
Catalogue status
Conditional

Battery calculation results

Status Configuration Quantity Usable energy Continuous power Current / run Voltage drop Max charge Max discharge BMS
Check Sunsynk W10.2 Single W10.2 pack 2 18.42 kWh 20.48 kW 120.0 A 0.30 V · 0.66% 400 A 400 A CAN
Battery bank checks Check
  • Inverter / battery compatibility: Use at least 2 complete system(s). Electrical screening passes; confirm the exact BMS profile and firmware with the manufacturer.
  • Recommended battery quantity: 2 selected; the recommended minimum is 2.
  • Maximum battery quantity: 2 is within the recorded maximum of 32.
  • Usable battery energy: 18,42 kWh meets the 10 kWh minimum.
  • Continuous battery power: 20,48 kW meets the 12 kW minimum.
  • Battery charge-current capacity: 400 A meets the 240 A minimum.
  • Battery discharge-current capacity: 400 A meets the 240 A minimum.
  • Battery cable voltage drop: 0,66 % is within the 5 % limit.
  • Battery cable current capacity: 120 A is within the 192 A limit.

05

Design assessment

Clear results show which values pass and which require a design change or data check.

Maximum PV voltage

518,29 V is within the 800 V limit. Includes the 25% design allowance.

Startup voltage

276,88 V meets the 160 V minimum.

MPPT lower limit

276,88 V meets the 200 V minimum.

MPPT upper limit

307,21 V is within the 650 V limit.

MPPT 1 string inputs

1 of 2 available string input(s) are used.

MPPT 1 operating current

11,35 A is within the 26 A limit.

MPPT 1 short-circuit current

15,01 A is within the 34 A limit. Includes the 25% design allowance.

MPPT 2 string inputs

1 of 1 available string input(s) are used.

MPPT 2 operating current

11,35 A is within the 13 A limit.

MPPT 2 short-circuit current

15,01 A is within the 17 A limit. Includes the 25% design allowance.

Maximum PV array power

8271,9 W is within the 15600 W limit. Includes the 25% design allowance.

Source-data checks

Items to confirm before production use

  • 46 active, calculation-ready panel models are loaded from SQL.
  • 12 reviewed inverters are loaded from SQL with each MPPT assessed separately.
  • The battery-bank section uses the reviewed SQL battery configurations and inverter compatibility records.