PV string · inverter · battery
Solar Design Calculator
Check panel strings, inverter limits, cable voltage drop and battery capacity from one design workspace.
01
Design conditions
These assumptions drive every string and battery calculation.
02
Inverter
Select the inverter whose limits will be used for the assessment.
- Rated output
- 12.00 kW
- Maximum PV power
- 15.60 kW
- Maximum PV voltage
- 800 V
- MPPT range
- 200–650 V
- Startup voltage
- 160 V
- MPPT trackers
- 2
- String inputs
- 2 + 1
- Operating current
- 26 A + 13 A
- Maximum Isc
- 34 A + 17 A
03
PV strings
Add up to ten string groups and assign every group to a physical inverter MPPT.
| String | MPPT | Panel model | Series | Parallel | Cable | Length | Actions |
|---|---|---|---|---|---|---|---|
m |
|||||||
m |
PV calculation results
| Status | String | MPPT | Panels | Cold Voc | Hot Vmp | Cold Vmp | Max Isc | Operating current | Nominal | Voltage drop |
|---|---|---|---|---|---|---|---|---|---|---|
| Pass | String 1 | MPPT 1 | 8 | 414.6 V | 276.9 V | 307.2 V | 12.01 A | 11.35 A | 3.64 kW | 4.32 V · 1.56% |
| Pass | String 2 | MPPT 2 | 8 | 414.6 V | 276.9 V | 307.2 V | 12.01 A | 11.35 A | 3.64 kW | 4.32 V · 1.56% |
String 1 checks Pass
- Cable voltage drop: 1,56 % is within the 5 % limit.
- Inverter maximum voltage: 518,29 V is within the 800 V limit.
- MPPT 1 operating current: 11,35 A is within the 26 A limit.
- MPPT 1 minimum: 276,88 V meets the 200 V minimum.
- MPPT 1 maximum: 307,21 V is within the 650 V limit.
String 2 checks Pass
- Cable voltage drop: 1,56 % is within the 5 % limit.
- Inverter maximum voltage: 518,29 V is within the 800 V limit.
- MPPT 2 operating current: 11,35 A is within the 13 A limit.
- MPPT 2 minimum: 276,88 V meets the 200 V minimum.
- MPPT 2 maximum: 307,21 V is within the 650 V limit.
04
Battery bank
Select a reviewed SQL battery configuration approved or conditionally screened for this inverter.
Selected battery configuration
- Voltage class
- LV
- Voltage range
- 44.8–57.6 V
- Usable per system
- 9.21 kWh
- Power per system
- 10.24 kW
- Recommended quantity
- 2
- Maximum quantity
- 32
- BMS
- CAN
- Catalogue status
- Conditional
Battery calculation results
| Status | Configuration | Quantity | Usable energy | Continuous power | Current / run | Voltage drop | Max charge | Max discharge | BMS |
|---|---|---|---|---|---|---|---|---|---|
| Check | Sunsynk W10.2 Single W10.2 pack | 2 | 18.42 kWh | 20.48 kW | 120.0 A | 0.30 V · 0.66% | 400 A | 400 A | CAN |
Battery bank checks Check
- Inverter / battery compatibility: Use at least 2 complete system(s). Electrical screening passes; confirm the exact BMS profile and firmware with the manufacturer.
- Recommended battery quantity: 2 selected; the recommended minimum is 2.
- Maximum battery quantity: 2 is within the recorded maximum of 32.
- Usable battery energy: 18,42 kWh meets the 10 kWh minimum.
- Continuous battery power: 20,48 kW meets the 12 kW minimum.
- Battery charge-current capacity: 400 A meets the 240 A minimum.
- Battery discharge-current capacity: 400 A meets the 240 A minimum.
- Battery cable voltage drop: 0,66 % is within the 5 % limit.
- Battery cable current capacity: 120 A is within the 192 A limit.
05
Design assessment
Clear results show which values pass and which require a design change or data check.
Maximum PV voltage
518,29 V is within the 800 V limit. Includes the 25% design allowance.
Startup voltage
276,88 V meets the 160 V minimum.
MPPT lower limit
276,88 V meets the 200 V minimum.
MPPT upper limit
307,21 V is within the 650 V limit.
MPPT 1 string inputs
1 of 2 available string input(s) are used.
MPPT 1 operating current
11,35 A is within the 26 A limit.
MPPT 1 short-circuit current
15,01 A is within the 34 A limit. Includes the 25% design allowance.
MPPT 2 string inputs
1 of 1 available string input(s) are used.
MPPT 2 operating current
11,35 A is within the 13 A limit.
MPPT 2 short-circuit current
15,01 A is within the 17 A limit. Includes the 25% design allowance.
Maximum PV array power
8271,9 W is within the 15600 W limit. Includes the 25% design allowance.
Source-data checks
Items to confirm before production use
- 46 active, calculation-ready panel models are loaded from SQL.
- 12 reviewed inverters are loaded from SQL with each MPPT assessed separately.
- The battery-bank section uses the reviewed SQL battery configurations and inverter compatibility records.